FX2N PLC FX2N-16MS

FX2N-16MS

Subscribe to get prices

Model: FX2N-16MS

Order No: FX2N-16MS

SKU: 1784788504739446260

Condition: New Sealed Under Guarantee

Size: 9.00 cm,8.80 cm,7.50 cm

Weight: 0.36kg

Product Selection Engineer:Hu

In Stock

Brief Introduction

FX2N-16MS

AC Power Supply/DC Input Type;Input: 8 points 24 V DC sink;Output: 8 points Triac

Description

Operation control system
Input/output control system
Programming language
Program memory Max. memory capacity
Built-in memory capacity/type
Memory cassette (Memory board)
Expansion memory (Expansion memory board)
Writing function during running
Protection
Real-time clock Clock function
Kinds of instructions Basic instructions
Applied instructions
Processing speed Basic instructions
Applied instructions
No. of input/output points No. of input points
No. of output points
Remote I/O number of points (CC-Link)
Total number of points
Device Input/output relay Input relay
Output relay
Auxiliary relay For general
For keeping
For keeping (battery backup fixed area)
For special
State Initial state
For general
For keeping
For annunciator
Timer (on delay) 100 ms
10 ms
1 ms accumulating type (capacitor keep)
100 ms accumulating type (capacitor keep)
Counter 16 bits up
16 bit increment (Battery backup)
32 bit both directions
32 bit both directions (Battery backup)
High-speed counter
Data register (32 bits when paired) 16 bits for general
16 bit for keeping (Battery backup)
16 bit for keeping (Battery backup fixed area)
16 bits for special
16 bits for index
Pointer For branching of JUMP and CALL
Input interruption
Timer interruption
Counter interruption
Nesting
Constant Decimal number (K)
Hexadecimal number (H)
Power supply specifications
Rated voltage
Allowable supply voltage range
Frequency rating
Allowable instantaneous power failure time
Power fuse
Rush current
Power consumption
24 V DC service power supply
5 V DC built-in power supply
Input specifications
No. of input points
Input connection type
Input type
Input signal voltage
Input impedance X000 to X007
X010 or more
Input signal current X000 to X007
X010 or more
ON input sensitivity current X000 to X007
X010 or more
OFF input sensitivity current
Input response time
Input signal form
Input circuit insulation
Indication of input operation
Output specifications
No. of output points
Output connection type
Output type
External power supply
Max. load Resistance load
Inductive load
Min. load
Open circuit leakage current
ON voltage
Response time OFF→ON
ON→OFF
Insulation of circuit
Indication of output operation
Stored-program repetitive operation method (dedicated LSI), with interrupt instructions
Batch processing system (when END instruction is executed), Input/output refresh instruction and pulse catch function are provided.
Relay symbol system + step-ladder system (SFC notation possible)
16000 steps
16000 steps including comments and file registers
8000 steps RAM (backed up by built-in lithium battery)
・FX-RAM-8 (2000/4000/8000/16000 steps)
・FX-EPROM-8 (2000/4000/8000/16000 steps)
・FX-EEPROM-4 (2000/4000 steps)
・FX-EEPROM-8 (2000/4000/8000 steps)
・FX-EEPROM-16 (2000/4000/8000/16000 steps)
FX2NC-ROM-E1 type function expansion memory board can be mounted on PLC version V3.00 and higher.
・Short mail send function
・Inverter operation control function
・16000 steps EEPROM (2000/4000/8000 steps also supported)
Provided (Program can be modified while the PLC is running.)
Password protection provided (with entry code function)
Built-in
1980 to 2079 (with correction for leap year) 2- or 4-digit year, accuracy within 45 seconds/month at 25 °C
・Sequence instructions: 27
・Step-ladder instructions: 2
Applied instructions: 132 kinds
0.08 μs/instruction
1.52 to several hundred μs/instruction
184 points or less (Extension combined number)
184 points or less (Extension combined number)
256 points or less including mounted I/O
256 points or less (Extension combined number)
X000 to X267 184 points (octal) Extension combined number
Y000 to Y267 184 points (octal) Extension combined number
M0 to M499 500 points
Battery-less backup area. Change to battery backup area by setting the parameters.
M500 to M1023 524 points
Battery backup area. Change to battery-less backup area by setting the parameters.
M1024 to M3071 2048 points
Battery backup fixed area. The area characteristics cannot be changed.
M8000 to M8255 256 points
S0 to S9 10 points
S10 to S499 490 points
Battery-less backup area. Change to battery backup area by setting the parameters.
S500 to S899 400 points
Battery backup area. Change to battery-less backup area by setting the parameters.
S900 to S999 100 points
Battery backup area. Change to battery-less backup area by setting the parameters.
T0 to T199 200 points (0.1 to 3,276.7 sec)
T200 to T245: 46 points (0.01 to 327.67 sec)
T246 to T249: 4 points (0.001 to 32.767 sec)
This retentive status is a battery backup fixed area. The area characteristics cannot be changed.
T250 to T255: 6 points (0.1 to 3,276.7 sec)
This retentive status is a battery backup fixed area. The area characteristics cannot be changed.
C0 to C99 100 points (Counting from 0 to 32,767)
Battery-less backup area. Change to battery backup area by setting the parameters.
C100 to C199 100 points (Counting from 0 to 32,767)
Battery backup area. Change to battery-less backup area by setting the parameters.
C200 to C219 20 points (Counting from -2,147,483,648 to +2,147,483,647)
Battery-less backup area. Change to battery backup area by setting the parameters.
C220 to C234 15 points (Counting from -2,147,483,648 to +2,147,483,647)
Battery backup area. Change to battery-less backup area by setting the parameters.
[32 bits high-speed up/down]
Up to 6 points can be used between C235 and C255.
1-phase: 60 kHz, 10 kHz
2-phase: 30 kHz, 5 kHz
The number of points that can be used and the input frequency are limited depending on the conditions of use.
Battery backup area. Change to battery-less backup area by setting the parameters.
D0 to D199 200 points
Battery-less backup area. Change to battery backup area by setting the parameters.
D200 to D511 312 points
Battery backup area. Change to battery-less backup area by setting the parameters.
D512 to D7999: 7488 points (D1000 and later can be set as file register points in 500-point units)
This retentive status is a battery backup fixed area. The area characteristics cannot be changed.
D8000 to D8255 256 points
V0 to V7, Z0 to Z7: 16 points
P0 to P127 128 points (For CJ instructions and CALL instructions, P63 jumps to END instruction)
I00□ to I50□: 6 points
I6□□ to I8□□: 3 points
I010 to I060: 6 points (For HSCS instructions)
[For master control]
N0 to N7: 8 points (For MC instructions)
16 bits: -32,768 to +32,767
32 bits: -2,147,483,648 to +2,147,483,647
16 bits: 0 to FFFF
32 bits: 0 to FFFFFFFF
 
100 to 240 V AC
85 to 264 V AC
50/60 Hz
Operation can be continued upon occurrence of instantaneous power failure for 10 ms or less.
When the supply voltage is 200 V AC, the time can be change to 10 to 100 ms by editing the user program.
250 V 3.15 A (3 A)
40 A max. 5 ms or less/100 V AC, 60 A max. 5 ms or less/200 V AC
25 W
250 mA or less
290 mA
 
8 points
Terminal block (M3 screw)
Sink
24 V DC ±10%
3.3 kΩ
7 mA/24 V DC
4.5 mA or more
1.5 mA or less
Approx. 10 ms
X000 to X017 (up to the main unit built-in number) have built-in digital filters, which can be changed to 0 to 60 ms in 1 ms increments using the application instructions or D8020.
When 0 is specified, X000 and X001 are 20 μs, and X002 to X017 are 50μs.
(FX2N-16N□ is supported within the range of X000 to X007.)
No-voltage contact input
NPN open collector transistor
Photocoupler insulation
LED is lit when input is on
 
8 points
Terminal block (M3 screw)
Triac output
85 to 242 V AC
1 output point/common terminal: 0.3 A or less
4 output points/common terminal: 0.8 A or less
8 output points/common terminal: 0.8 A or less
15 VA/100 V AC
30 VA/200 V AC
0.4 VA/100 V AC
1.6 VA/200 V AC
1 mA/100 V AC
2 mA/200 V AC
1 ms or less
10 ms or less
Photo-thyristor insulation
LED on panel lights when photo-thyristor is driven.

Function specifications

Built-in high-speed counter function
1-phase 1-count input
1-phase 2-count input
2-phase 2-count input
 
[C235, C236]
Up to 2 points: Up to 60 kHz
When used High-speed comparison SET/RESET: 10 kHz
When used High-speed zone compare HSZ: 5.5 kHz
[C237 to C245]
Up to 4 points: Up to 10 kHz
When used High-speed comparison SET/RESET: 10 kHz
When used High-speed zone compare HSZ: 5.5 kHz
The total frequency processed by the PLC with the high-speed counter, pulse output instruction, and pulse density instructions (for 2-phase counters, add twice the input frequency) is a maximum of 20 kHz.
When using the high-speed comparison SET/RESET, the total frequency processed by the PLC with the high-speed counter, pulse output instruction, and pulse density instruction (add double the input frequency when using a 2-phase counter) is a maximum of 11 kHz.
The total frequency processed by the PLC with the high-speed counter, pulse output instruction, and pulse density instructions (for 2-phase counters, add twice the input frequency) is a maximum of 5.5 kHz.
[C246]
Up to 1 point: Up to 60 kHz
When used High-speed comparison SET/RESET: 10 kHz
When used High-speed zone compare HSZ: 5.5 kHz
[C247 to C250]
Up to 2 points: Up to 10 kHz
When used High-speed comparison SET/RESET: 10 kHz
When used High-speed zone compare HSZ: 5.5 kHz
The total frequency processed by the PLC with the high-speed counter, pulse output instruction, and pulse density instructions (for 2-phase counters, add twice the input frequency) is a maximum of 20 kHz.
When using the high-speed comparison SET/RESET, the total frequency processed by the PLC with the high-speed counter, pulse output instruction, and pulse density instruction (add double the input frequency when using a 2-phase counter) is a maximum of 11 kHz.
The total frequency processed by the PLC with the high-speed counter, pulse output instruction, and pulse density instructions (for 2-phase counters, add twice the input frequency) is a maximum of 5.5 kHz.
[C251]
Up to 1 point: Up to 30 kHz
When used High-speed comparison SET/RESET: 5 kHz
When used High-speed zone compare HSZ: 4 kHz
[C252 to C255]
Up to 2 points: Up to 5 kHz
When used High-speed comparison SET/RESET: 4 kHz
When used High-speed zone compare HSZ: 4 kHz
The total frequency processed by the PLC with the high-speed counter, pulse output instruction, and pulse density instructions (for 2-phase counters, add twice the input frequency) is a maximum of 20 kHz.
When using the high-speed comparison SET/RESET, the total frequency processed by the PLC with the high-speed counter, pulse output instruction, and pulse density instruction (add double the input frequency when using a 2-phase counter) is a maximum of 11 kHz.
The total frequency processed by the PLC with the high-speed counter, pulse output instruction, and pulse density instructions (for 2-phase counters, add twice the input frequency) is a maximum of 5.5 kHz.

General specifications

Ambient temperature
Ambient humidity
Vibration resistance Installed on DIN rail Frequency: 10 to 57 Hz
Frequency: 57 to 150 Hz
Direct installing Frequency: 10 to 57 Hz
Frequency: 57 to 150 Hz
Shock resistance
Noise resistance
Dielectric withstand voltage
Insulation resistance
Grounding
Working atmosphere
Working altitude
0 to 55°C (32 to 131°F) when operating and -20 to 70°C (-4 to 158°F) when stored
35 to 85%RH (no condensation) when operating
Half amplitude: 0.035mm Sweep Count for X, Y, Z: 10 times (80 min in each direction)
The criterion is shown in IEC61131-2.
Acceleration: 4.9 m/s2 Sweep Count for X, Y, Z: 10 times (80 min in each direction)
The criterion is shown in IEC61131-2.
Half amplitude: 0.075 mm Sweep Count for X, Y, Z: 10 times (80 min in each direction)
The criterion is shown in IEC61131-2.
Acceleration: 9.8 m/s2 Sweep Count for X, Y, Z: 10 times (80 min in each direction)
The criterion is shown in IEC61131-2.
147 m/s2 Acceleration, Action time: 11 ms, 3 times by half-sine pulse in each direction X, Y, and Z
The criterion is shown in IEC61131-2.
By noise simulator at noise voltage of 1,000 Vp-p, noise width of 1 μs, rise time of 1 ns and period of 30 to 100 Hz
Perform dielectric withstand voltage test at the following voltage between each terminals and the main unit ground terminal.
Between power supply terminal (AC power supply) and ground terminal: 1.5 kV AC for 1 min
Between 24 V DC service power supply connected to input terminal (24 V DC) and ground terminal: 500 V AC for 1 min
Between output terminal (triac) and ground terminal: 1.5 kV AC for 1 min
Perform insulation resistance test at the following voltage between each terminals and the main unit ground terminal.
Between power supply terminal (AC power supply) and ground terminal: 5 MΩ or higher by 500 V DC insulation resistance tester
Between 24 V DC service power supply connected to input terminal (24 V DC) and ground terminal: 5 MΩ or higher by 500 V DC insulation resistance tester
Between output terminal (triac) and ground terminal: 5 MΩ or higher by 500 V DC insulation resistance tester
Class D grounding (grounding resistance: 100 Ω or less)
(Common grounding with a heavy electrical system is not allowed)
Ground the PLC independently or jointly.
Free from corrosive or flammable gas and excessive conductive dusts
2000 m or less
Do not use the PLC under pressure higher than the atmospheric pressure. Doing so may damage the PLC.